Back to Blog

Gas boiler Repair Experts fix Vaillant Eco Tec Boiler in Wibsey BD6

Gas Boiler Experts Wibsey BD6

We Fix Faulty  Vaillant Eco Tec Boiler

01274 317169

We fix a Vaillant Eco Tec Boiler with a Faulty Central Heating Pump.

We are the boiler Experts in Wibsey BD6. Boiler issues can severely curtail your comfort in your home, especially during the colder months

As Gas Boiler Experts Wibsey BD6 One common issue we find that homeowners encounter is an Vaillant Eco Tec Boiler with a faulty circulating Pump, these components in particularly without proper servicing and a magnetic filter. we delve into the steps involved in repairing these crucial parts, ensuring your heating system operates efficiently and reliably.

Call us on 01274 317169 today for your boiler repair.

Or click HERE to fill out your details and we will give you a call back

Identifying the Problem

When a Vaillant Eco Tec Boiler starts showing signs of failure, it’s crucial to diagnose the problem accurately.

Boiler Repair Wibsey BD6   Call 01274 317169

The most common errors on the display panel on a Vaillant Eco Tec Boiler are:

No Water Flow

Boiler Flow Overheat

On Vaillant Eco Tec Boilers, the F75 code will show up

The pump in your Vaillant Eco Tec Boiler is essential for circulating hot water throughout your heating system to supply heat to your radiators

Symptoms that suggest a fault in the pump:

Banging or popping noise within the boiler sometimes referred as kettling.

 A lack of hot water or heating.

visible leaks around the boiler.

If you notice any of these issues in your home in Wibsey BD6, it’s time to consider a professional boiler repair service such as the Bradford Boiler Company

Choosing the Right Service in Wibsey BD6

Selecting a Gas Engineer Expert to repair your boiler in Wibsey BD6 is crucial.

As we are Gas Safe Registered you need look no further than the Bradford Boiler Company. We are the gas Boiler Experts in Wibsey BD6.

As professionals with the right credentials and qualifications, we ensure your boiler repair is safe and effective, adhering to the highest standards of excellence and complying with local regulations and manufacturer guidelines.

 

What a Repair Entails

The whole process begins with a thorough inspection of the boiler to confirm what the issue is. Here’s how a typical repair might unfold:

Diagnosing the boiler fault

Our Gas Boiler Expert will assess the boiler to verify the fault. This might involve checking the pressure levels, listening to the boiler in operation for abnormal sounds, and looking for any error codes displayed on the boiler’s control panel when the boiler to fault mode.

Is It The Pump At Fault?

With Vaillant Boiler a common fault when the error code F75 is shown .is that pressure sensor is faulty. At the Bradford Boiler Company we can diagnose correctly the faulty part saving you time and money.

 

Replacing the Pump

If the pump is found to be faulty, it will be replaced. The process involves draining your boiler commonly with a wet Vac to remove the water quickly, removing the old pump, and installing a new one. we will then check to ensure it is correctly aligned and securely fitted.

Determining the cause of the fault

We will inspect the old pump to determine whether wear and tear is the issue or if there is an underlying cause that needs fixing.

Testing

After the repairs are made, the boiler is then tested to make sure it is working properly. This includes running the system to check for any leaks and verifying that the heating and hot water are functioning properly.

Preventive Maintenance

Regular maintenance is the key to extending the lifespan of your Vaillant Eco Tec Boiler boiler.

Annual servicing by a qualified engineer can help detect potential issues before they turn into costly faults and repairs. Regular Servicing will go some way to help with keeping your boiler reliable and fault free.

Conclusion

A faulty pump can significantly impact the performance of your Vaillant Eco Tec Boiler. Therefore, addressing these issues promptly ensures optimal functioning and reliability. By choosing a skilled, Gas Safe registered technician in Wibsey BD6, you can have total confidence, that we conduct your boiler repairs safely and effectively. Remember, preventive maintenance is your best strategy against unexpected breakdowns, ensuring your boiler remains in excellent condition for years to come.

For residents of Wibsey BD6, addressing boiler issues promptly not only guarantees the comfort of your home but also enhances the efficiency and longevity of your heating system.

Boiler Repair Wibsey BD6   Call 01274 317169

Back to Blog

Vaillant F22 Fault Code Error Low Pressure How To fix

Vaillant F22 Fault Code Low Pressure

What is the F22 Error on Vaillant Combi Boilers

we will look into the causes behind the Vaillant F22 Fault Code error and explore potential solutions to resolve it.

Vaillant F22 Fault Code error

The F22 error on an Vaillant Combi boiler indicates a fault in the sealed system pressure reading on the boiler. It typically occurs when the water pressure reading within the boiler drop below Approximately 0.7 bar.

you are able to view how much pressure have by looking at the pressure gauge located generally on the front of the boiler The 22 Error can prevent your boiler from firing up to produce hot water and central heating.

Topping your Vaillant boiler with the filling normally resolve the issue

Possible Causes of the Repeated F22 fault error code and how to fix it

Why Does The Vaillant boiler F22 Error Keep Happening?

Periodically over time due to the heating and cooling over time the water will evaporate away out the microscpic joints in your central heating system.

The time this takes varies from each central heating system but,

I have found from experience it happens more often on systems with plastic pipe.

Saying this though you shouldnt really have to be doing more often than once or twice a year. Although I have known some centralheating to have not needed topping up in over 4/5 years it really does vary from system to system.

Other Common Causes Of The Vaillant F22 Fault Code Error

  • A Cracked heat Exchanger inside the boiler.

  • A Faulty expansion vessel within the boiler.

  • A faulty pressure relief valve withiin the boiler.

  • a leak within the boiler on another component.

  • Leaking pipework on your central heating system.

  • A leaking Radiator.

  • A leaking Radiator Valve.

All these faults above will cause your Vaillant Boiler and central heating system to lose water pressureiver time causing the F22 error.

Fixing the Vaillant F22 Code Error

The first thing would be to check your pipework, radiators and radiator valves.

If you cant find a leak on your central heating system then you should contact a gas safe registered engineer to investigate the problem to get it resolved in speedy fashion.

They can diagnose diagnose the specific cause of the error and take appropriate measures to rectify the issue The solution may involve replacing faulty components.

How do I get this fault Fixed.

You will need the service of a registered Gas safe Engineer

so why not give Bradford Boiler installation company a call on 01274 317169

fill out your details by clicking here on our contact us page.

We can visit and Diagnose what the issue is and offer a speedy repair.

Take A Look at Our Other Vaillant Error Code Blogs

Top 5 Common Vaillant Fault Codes

 

Back to Blog

Vaillant F75 Fault Code What Causes This

Vaillant F75 Fault Code

Is this a Common Issue with Vaillant Combi Boilers?

Does your boiler have the Vaillant F75 fault Code?

At Some point in the future if you have an older vaillant combi boiler you will come across the Vaillant F75 fault code at some point during its lifespan.

While these boilers are known for their efficiency and reliability, like every piece of machinery with moving parts they can breakdown whilst working in your home.

So lets take a look into what the F75 fault entails, its potential causes,

The F75 fault code is specific to  Vaillant combi or system boilers that work on sealed systems.

It indicates a problem with the pressure inside the Boiler. Specifically.

What factors can lead to the Vaillant F75 Fault Code

Identifying the root cause is crucial for successful troubleshooting and getting your back up and running again.

One common reason is a leak in the Central Heating System, which can cause a gradual drop in water pressure over a period of time.

Check your central heating system including valves, radiators and pipework for any visible leaks. Additionally, the expansion vessel, responsible for maintaining a stable water pressure, might be faulty, leading to pressure fluctuations and triggering the F75 fault.

The most Common cause is a faulty pressure sensor itself. With constant use the sensor can wear out or become clogged with Sludge, causing inaccurate readings and the F75 fault is triggered. Once this fault happens it is essential that the sensor is replaced. We have tried in the past to clean these but it has never worked.

Another cause is a faulty pump that has either shortcircuited or seized up. This also causes the Vaillant boiler F75 fault code as the sensor is looking for a spike in pressure caused by the pump activating. If the sensor cannot detect this pressure it will go to the F75 fault.

If you have this fault then the chances are that you dont have a good quality magnetic fillter Magnetic Filter. A magnetic filter catches magnetic and Detritus in the system this will help to stop the clogging up and help keep your pump in good condition.

How do I get this fault Fixed.

You will need the service of a registered Gas safe Engineer

so why not give Bradford Boiler installation company a call on 01274 317169

We can visit and Diagnose what the issue is and offer a speedy repair.

Take A Look at Our Other Vaillant Error Code Blogs

Top 5 Common Vaillant Fault Codes